Paper-83
05 May, 2020
Selective estimation of three-phase mains current for shunt active power filter
Abstract
In the paper a method of the three phase current harmonics observers configuration for selective detection of the distortions is proposed. The relationship between the observer tuning gains and the speed of the estimation preserving the selectivity properties is obtained. Simulation and experimental results confirm the theoretical findings and demonstrate the effectiveness of the proposed solution for shunt active power filters with selective harmonics compensation.
Authors
- Yurii Zaichenko (National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”)
- Sergei Peresada (Igor Sikorsky Kyiv Polytechnic Institute)
- Serhii Dymko ( National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”)